.\" Copyright © 2009 Keith Packard <keithp@keithp.com>
|
|
.\"
|
|
.\" This program is free software; you can redistribute it and/or modify
|
|
.\" it under the terms of the GNU General Public License as published by
|
|
.\" the Free Software Foundation; either version 2 of the License, or
|
|
.\" (at your option) any later version.
|
|
.\"
|
|
.\" This program is distributed in the hope that it will be useful, but
|
|
.\" WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
.\" MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
|
.\" General Public License for more details.
|
|
.\"
|
|
.\" You should have received a copy of the GNU General Public License along
|
|
.\" with this program; if not, write to the Free Software Foundation, Inc.,
|
|
.\" 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
|
.\"
|
|
.\"
|
|
.TH AO-LOAD 1 "ao-stmload" ""
|
|
.SH NAME
|
|
ao-stmload \- flash a program to an STM32-based AltOS device
|
|
.SH SYNOPSIS
|
|
.B "ao-stmload"
|
|
[\-D \fI/dev/sgX\fP]
|
|
[\--device \fI/dev/sgX\fP]
|
|
[\--cal \fIradio-calibration\fP]
|
|
[\--serial \fserial-number\fP]
|
|
\fIfile.elf\fP
|
|
.SH DESCRIPTION
|
|
.I ao-stmload
|
|
loads the specified .elf file into the target device flash memory,
|
|
using either existing serial number and radio calibration values or
|
|
taking either of those from the command line.
|
|
.SH OPTIONS
|
|
.TP
|
|
\-D /dev/sgX | --device /dev/sgX
|
|
This targets an STlinkV1 connection rather than STlinkV2
|
|
.TP
|
|
\-s serial-number | --serial serial-number
|
|
This programs the device serial number into the image. If no serial
|
|
number is specified, then the existing serial number, if any, will be
|
|
read from the device.
|
|
.TP
|
|
\-c radio-calibration | --cal radio-calibration This programs the
|
|
radio calibration value into the image for hardware which doesn't have
|
|
any eeprom storage for this value. If no calibration value is
|
|
specified, an existing calibration value will be used. The value here
|
|
can be computed given the current radio calibration value, the
|
|
measured frequency and the desired frequency:
|
|
.IP
|
|
cal' = cal * (desired/measured)
|
|
.IP
|
|
The default calibration value is 7119667.
|
|
.SH USAGE
|
|
.I ao-stmload
|
|
reads the specified .elf file into memory, edits the image to
|
|
customize it using the specified serial number and radio calibration
|
|
values. It then connects to the debug dongle and writes the program to
|
|
the target device flash memory.
|
|
.SH AUTHOR
|
|
Keith Packard
|